- Environmentally friendly heating protection concentrate for hot water heating systems, underfloor heating systems or capillary heating systems
- Optimum protection against corrosion through innovative OAT inhibitors
- Prevents sludge formation and other deposits
- Improves heat transfer
- pH-value stabilizing
- Hard water stable up to a total hardness of 15 °dH
- Free of molybdenum
- Miscible with water in any ratio
Key data
- Nitrite-free, secondary amine-free, borate-free, molybdenum-free, free of 2-ethylhexanoic acid
- Corrosion protection on OAT basis (Organic Acid Type)
- Biodegradable
- pH-value stabilizing properties
- Lightly dispersing properties
- Colour: clear
- Specific weight: 1.1 g/ml (DIN 51757)
- pH value at 0.5% application concentration: 8.3±0.15 (ASTM-D 1287)
- Electrical conductivity at 0.5% application concentration in demineralised water: approx. 600 μS/cm
- No hazardous material, no hazardous substance
- Water hazard class: WGK 1
- Environmentally friendly heating protection concentrate for hot water heating systems, underfloor heating systems or capillary heating systems
- Conditioning of new or cleaned heating circuits with demineralised water
- VDI 2035 guideline value for electrical conductivity with low-salt operation is adhered to
- Optimum protection against corrosion through innovative OAT inhibitors
- Prevents sludge formation and other deposits
- Improves heat transfer
- pH-value stabilizing
- Nitrite, phosphate and secondary amine free
- Miscible with water in any ratio
- No hazardous material, no dangerous goods
Key data
- Nitrite-free, phosphate-free, secondary amine-free, borate-free, zinc-free, molybdenum-free, free of 2-ethylhexanoic acid
- Corrosion protection on OAT basis (Organic Acid Type)
- Biodegradable
- pH-value stabilizing properties
- No dispersing properties
- Colour: clear, light yellow
- Specific weight: 1.039 ± 0.004 g/ml (DIN 51757)
- pH value: 8.60 ± 0.2 (ASTM-D 1287) (at 0.5% application concentration)
- Electrical conductivity: approx. 65 μS/cm (*) (at 0.5% application concentration)
- No hazardous material, no hazardous substance
- Environmentally friendly heat transfer and antifreeze agent for water heating systems
- Can be used to protect against frost damage when heating system is switched off in commercial and private systems
- Optimum corrosion protection for all metals used in the system
- (also copper and aluminium)
- Prevention of layer formation and deposits
- Mixable with water and individually adjustable to the desired frost protection
- Nitrite, phosphate and secondary amine free
- No hazardous substances, no hazardous goods, no CMR substances
Key data
- Nitrite-free, phosphate-free, secondary amine-free, borate-free, silicate-free, free from 2-ethylhexanoic acid
- Corrosion protection on OAT basis (Organic Acid Type)
- Biodegradable
- Colour: clear, slightly yellowish
- Frost protection base: 1.2-propanediol
- Specific weight: 1.05 g/ml (DIN 51757)
- pH value (1:1 with neutral water): 7.5 -8.5 (ASTM-D 1287)
- Thermal conductivity (at 20 °C): 0.22 W/m*K
- Boiling point (°C):> 138 (ASTM-D 1120)
- Flash point (°C): > 100 (ASTM-D 51758)
- No dangerous goods - Water hazard class 1
- Mobilisation and dispersion of loose components in the heating system
- Suitable for hot water heating systems with a high degree of corrosion and sludge formation
- Advantage: Circulation water does not have to be replaced
- Ideal as a preparatory measure for sustainable cleaning of the entire system with the mobile filtration system coracon® SLIMY 8
- Recommendation: After the cleaning process it is best to use a preventive corrosion protection such as coracon® HE 6+ or coracon® VE 9
Key data
- Nitrite-free, phosphate-free, secondary amine-free, borate-free, zinc-free
- Biodegradable
- Strong dispersing properties
- Dosage: > 0,2 Vol. % - 0,4 Vol. %
- Temperature resistant: up to 150 °C
- Colour: clear, ochre
- Specific weight: 1.147 ± 0.015 g/ml (DIN 51757)
- pH value: 9.8 ± 0.3 (ASTM-D 1287)
- Flash point (°C): > 100 (ASTM-D 51758)
- No hazardous material, no hazardous substance
- Water hazard class 1
- Well-founded, laboratory analysis of the heating water with detailed analysis report and recommendations for action
- Fields of application: General control of the system water quality, commissioning of a new heating system, search for a cause of damage as part of an expert's report.
- Clarification of requirements and follow-up inspection of corrosion protection measures and/or system cleaning
- Parameters in fresh water: pH value, total hardness, carbonate hardness, electrical conductivity, iron, copper, aluminium, molybdenum
- Parameters in heating water: pH value, total hardness, carbonate hardness, electrical conductivity
- For filtration of dirt and sludge during operation without draining the circuit water
- Filter flow rate maximum: 8 m³/h
- Filter fineness: optionally 1µm, 15µm, 40 µm
- Filter area: 1.7 m²
- Max. Operating pressure: 6 bar
Key data
Electrics
- Electrical connected load: 220 V -250 V 50 Hz
- Engine power:0,36 kW
- Engine speed:2900 1/min
- Protection class: IP 54
Filtration
- Filter flow rate maximum: 8 m³/h
- Filter fineness: optional 1μm, 15μm, 40 μm
- Filter area: 1.7 m²
- Max. Operating pressure: 6 bar
Ports
- Admission: Ball valve 1"
- Outlet: Ball valve 1"
- Mobile desalinating/softening device for the production of soft water or fully desalinated water
- Simply connect directly to the drinking water system on site
- Quick Change tank system for fast emptying of the mixed bed resin within only 30 seconds
- Delivered ready for connection and completely filled (MB resin)
Download product sheet coracon® SALTY 7
- Efficient and sustainable renovation concept for heating systems during operation
- Mobilisation of rust, deposits and sludge with the aid of active chemical components
- Filtering out the deposits by off-line filtration using the coracon® SLIMY 8
- Downstream softening/desalination by coracon® SALTY 7 to a VDI 2035 compliant conductance of < 10 µS/cm
- Creation of a permanent protective layer by coracon® VE9
- Through the interaction of different components, the heating water is regenerated, stabilised and permanently protected in one process
- Compact electromagnetically driven vibratory armature piston pump for filling heating systems with anti-corrosion and/or cleaning fluids
- Convenient screwing of the pump directly onto the canister
- Easy connection to the heating system with enclosed hose
- Pump can be operated at intervals or in continuous operation for several hours
- Integrated thermocouple for overload protection
- Automatic switch-off in case of overload and automatic restart after cooling process